fixed windows
All Aluminum Thermally Broken Fixed Window (TS.77)
Explore All Aluminum Thermally Broken Fixed Window (TS.77) for custom window schedules. Compare the photographs, frame construction and available options before requesting project pricing.
Made to order. Price, approved dimensions and lead time are confirmed in the quote.

Planning this system for custom window schedules
This window maximizes transparency and aesthetic appeal, designed for seamless integration into modern architectural spaces.
All Aluminum Thermally Broken Fixed Window (TS.77): maximum panel height 180"; maximum panel width 180"; stile 1 ⅜"; style Modern.
Give each window an opening ID, room name and measurement convention. Decide where ventilation is needed, which windows remain fixed and whether matching frames or sightlines matter across adjacent openings.
Photography & design details
Explore the options
Options for this system. Availability and combinations are confirmed in the final quote. Screen colors do not replace physical finish samples.
Colors & Finishes
Divided Lites
Glass
Additional Options
Specifications & performance
Manufacturer-published values are specific to the stated system and tested configuration. Panel dimensions are not overall rough-opening dimensions. A dash means no value is supplied in that field.
Performance
- U-Factor
- -
- SHGC
- -
- Impact Rated
- -
- AAMA Tested
- Yes
- Design Pressure (psf)
- ± 100.25 psf
- Air Infiltration (cfm/ft2)
- 0.012 cfm/ft² @ 1.57 psf (Limit: 0.200 cfm/ft²)
- Water Penetration Resistance (psf)
- 720 Pa (15.04 psf)
- Structural Test Pressure (psf)
- ± 150.38 psf (1.5× DP)
- Florida Approval #
- -
Specifications
- Maximum Panel Height
- 180"
- Minimum Panel Height
- 12"
- Maximum Panel Width
- 180"
- Minimum Panel Width
- 12"
- Maximum Panel Weight
- -
- Panel Depth
- 3 ¹⁄₁₆"
- Maximum Number of Panels
- -
- Stile
- 1 ⅜"
- Rail
- 1 ⅜"
Design and installation planning
Give each window an opening ID, room name and measurement convention. Decide where ventilation is needed, which windows remain fixed and whether matching frames or sightlines matter across adjacent openings.
Plan the opening
Your project
Request a quote
All Aluminum Thermally Broken Fixed Window (TS.77). Give each window an opening ID, room name and measurement convention. Decide where ventilation is needed, which windows remain fixed and whether matching frames or sightlines matter across adjacent openings.
Start with approximate dimensions if the opening has not been verified. This request begins project review; it is not an order or payment.